INPUT
|
|
Connectors:
|
XLR and 1/4" TRS (Pin 2 and tip
hot)
|
|
Type:
|
Electronically balanced/unbalanced,
RF filtered
|
|
Impedance:
|
Balanced > 50 kOhm, unbalanced >25
kOhm
|
|
Maximum Input Level:
|
> +24 dBu balanced or unbalanced
|
|
CMRR:
|
Typically >50 dB at 1 kHz
|
|
OUTPUT
|
|
Connectors:
|
XLR and 1/4" TRS (Pin 2 and tip
hot)
|
|
Type:
|
Servo-balanced/unbalanced, RF filtered
|
|
Impedance:
|
Balanced 120 Ohm, unbalanced 60 Ohm
|
|
Max Output Level:
|
> +21 dBm balanced, > +20
dBm unbalanced
|
|
SIDECHAIN INPUT
|
|
Connector:
|
1/4" TS
|
|
Type:
|
Unbalanced, RF filtered
|
|
Impedance:
|
>10 kOhm
|
|
Max Input Level:
|
>+24 dBu
|
|
SIDECHAIN OUTPUT
|
|
Connector:
|
1/4" TRS (tip hot)
|
|
Type:
|
Impedance balanced, RF filtered
|
|
Impedance:
|
Balanced 2 kOhm, unbalanced 1 kOhm
|
|
Max Input Level:
|
>+21 dBu balanced or unbalanced
|
|
SYSTEM PERFORMANCE
|
|
Bandwidth:
|
20 Hz to 20 kHz, +0/0.5 dB
|
|
Frequency Response:
|
0.35 Hz to 90 kHz, +0/-3 dB
|
|
Noise:
|
< -96 dBu, unweighted, 22 kHz measurement
bandwidth
|
|
Dynamic Range:
|
> 118dB, unweighted
|
|
THD + Noise:
|
0.008% typical at +4 dBu, 1 kHz,
unity gain
0.08% typical at +20 dBu, 1 kHz, unity gain
< 0.1% any amount of compression up to 40 dB, 1 kHz
|
|
IMD:
|
< 0.1% SMPTE
|
|
Interchannel Crosstalk:
|
< -80dB, 20 Hz to 20 kHz
|
|
Stereo Coupling:
|
True RMS Power Summing!"
|
|
COMPRESSOR
|
|
Threshold Range:
|
-40 dBu to +20 dBu
|
|
Ratio:
|
1:1 to infinity:1
|
|
Threshold Characteristic:
|
Selectable OverEasy® or hard
knee
|
|
Attack/Release Chracteristic:
|
Auto Dynamic!"
|
|
Attack/Release Modes:
|
Selectable Manual or Auto
|
|
Manual Attack Time::
|
Scalable program-dependent
|
|
Manual Release time:
|
Scalable program-dependent
|
|
Auto Attack Time:
|
Program-dependent
|
|
Auto Release Time:
|
Program-dependent
|
|
Output Gain:
|
-20 to +20 dB
|
|
LIMITER
|
|
Threshold Range:
|
+4 dBu to +24 dBu (off)
|
|
Ratio:
|
infinity:1
|
|
Limiter Type:
|
PeakStopPlus!" two-stage limiter
|
|
Stage 1:
|
PeakStop!" brickwall limiter
|
|
Attack time:
|
Zero
|
|
Release Time:
|
Zero
|
|
Stage 2:
|
Predictive intelligent program limiter
|
|
Attack Time:
|
Program-dependent
|
|
Release Time:
|
Program-dependent
|
|
EXPANDER/GATE
|
|
Threshold Range:
|
Off to +15dBu
|
|
Ratio:
|
|
1:1 to 30:1
|
|
Attack Time:
|
< 100 µsec
|
|
Release Time:
|
Program-dependent
|
|
FUNCTION SWITCHES
|
|
SC Ext.:
|
Routes the external sidechain input
signal to the detector
|
|
SC Mon:
|
Routes the sidechain signal to the output,
interrupting the normal audio
|
|
OverEasy®:
|
Activates the OverEasy compression function
|
|
Contour:
|
Activates the frequency-dependent detector
function
|
|
Auto:
|
Activates automatic program-dependent
attack and release times, disabling the manual Attack
and Release controls
|
|
I/O Meter:
|
Switches between monitoring input and
output levels on the Input/Output Level meter
|
|
Bypass:
|
Activates the direct input-to-output
hard-wire relay bypass. Relay automatically hard-wire
bypasses unit at power-down and provides a power-on
delay of 1.5 sec.
|
|
Operating Level (rear panel):
|
Switches the nominal operating level
between -10 dBV and +4 dBu simultaneoulsy for both input
and output levels
|
|
ST Link:
|
Link both channels for stereo operation.
Channel One becomes the master
|
|
INDICATORS
|
|
Gain Reduction Meter:
|
12-segment LED bar graph at 1, 2, 4,
6, 9, 12, 15, 18, 21, 24, 27 and 30 dB
|
|
Input/Output Meter:
|
8-segment LED bar graph at -24, -18,
-12, -6, 0, +6, +12, and +18 dBu
|
|
Compressor Threshold Meter:
|
3-segment LED bar graph at Below (-),
OverEasy and Above (+)
|
|
Exp/Gate Threshold Meter:
|
2-segment LED bar graph at Below (-)
and Above (+)
|
|
Limiter, Threshold Meter:
|
1 LED to indicate PeakStopPlus!"
limiting
|
|
Function Switches:
|
LED indicator for each front-panel switch
|
|
OPTIONS - Output Transformer
|
|
Per Channel:
|
Jensen® JT-123-dbx or JT-11-dbx,
BCI RE-123-dbx or RE-11-dbx
|
|
POWER SUPPLY
|
|
Operating Voltage:
|
100-120 VAC 50/60 Hz 200-240 VAC 50/60
Hz
|
|
Power Consumption:
|
20 Watts
|
|
Fuse:
|
100-120 VAC: 250 mA Slow Blow
|
|
|
200-240 VAC: 125 mA Type T
|
|
Mains Connection:
|
IEC receptacle
|
|
PHYSICAL
|
|
Dimensions:
|
1.75"Hx19"Wx9"D (4.4cmx48.3cmx20.1cm)
|
|
Weight:
|
5.1 lbs. (2.3 kg)
|
|
Shipping Weight:
|
7.5 lbs. (3.4 kg)
|
|
Note: Specifications subject to change